profile
products
feedback
中文版
□Phantom Burden□           the last   the next  

Model Phantom Burden DAC-PBVC-7
PHANTOM BURDEN
○Application Features:
① This set is a new-type burden(Japanese Patent Product) combined by actual burden of resitance and reactance of meter transformer and convertor.
② PT,CT shared,minitype and portable
③ Main Unit Max. Set 100VA。
④ Zero burden can be set using compensation loop
⑤ 500VA(PT)burden can be set using option enlarged load box.

○Technical Index:
① Rated Secondary Voltage:110V,110/√3V in PT Mode
Rated Secondary Current:5A,1A in CT Mode
② Measuring Voltage:2~120% of the Rated in PT Mode
Measuring Current:2~120% of the Rated in CT Mode
③ Burden Power Rate:Lag 0.20~1~0.80 Lead
④ Set Burden: 0.000~100.0VA in PT Mode
0.000~100.0VA in CT Mode
⑤ Down-lead Compensation: 0~1.000Ω in CT Mode
⑥ Burden Set Accuracy:±4% Less than 1/10 of the Rated ±10%

 


⑦ Output Interface:GP-IB Standard Setup
⑧ Operating Power Supply:AC220V 50/60Hz
⑨ Size and Weight:W430×H200×D450mm 20kg
⑩ Other Options:
○ Enlarged Burden BoxDAC-FBV-1(100VA for PT)
DAC-FBV-2(400VA for PT)
DAC-FBC-1(100VA for CT)
○ Burden Setup for PT,CT
DAC-PBV-7 for PT
DAC-PBC-7 for CT

□Instrument Transformer Test Set□
Instrument Transformer Test Set Model DAC-VCTT-6
INSTRUMENT TRANSFORMER TEST SET
○Testing Object:PT, CT(transformer, convertor)
○Application Features:Measure ratio error and phase angle of PT or CT, easy to handle, minitype and portable, field-applicable.
○Technical Index:
① Measuring Method Comparative Test against Standard Meter
② PT, CT: ○ Transformer Rated Secondary Voltage 220V,220/√3V
            ○ Convertor Secondary Rated Current 5A、1A
③ Measuring Range:
Rated Voltage˙Current:2~200%

Measuring Range Display
Ratio Error Phase Angle Ratio Error Phase Angle
2% 20m 0~±1.999% 0~±19.99m
20% 200m 0~±19.99% 0~±199.9m
④ Resolution:
Measuring Range Ratio Error Phase Angle
2%0.001% 0.01m
20%0.01% 0.1m

 

⑤ Measuring Accuracy:
Ratio Error±(3%RDG Error+4digits)
Phase Angle ±(3%RDG Error +4digits)
⑥ Operating Power Supply: AC220V 50/60Hz
⑦ Size and Weight: W430×H180×D320 10kg

□可搬型虚负载试验装置□
□精密三相3线式虚负载试验装置□
电能表现场校验用虚负载装置Model DAC-PPS-1
○Measuring Object:Dummy load for ammeter field testing
○Application:can be assembled with phantom burden of single-phase,three-phase (3 cables), three-phase (4 cables) ammeter field testing, uninfluenced by voltage and frequency changes, ensure a stable testing.

○Technical Index:
1. Testing Objects:12W,33W,34W
2. Rated Voltage:220V、100V
3. Rated Current:5A
4. Measuring Voltage:80、90、100、110、120%  of Rated Voltage
5. Measuring Current:6、5、2.5、1、0.5、0.25A
6. Latent Flunctuation:110% of Rated Voltage
7. Pick-up Current:50、20、15、12.5mA
8. Output Stability:±0.1%
9. Output Wave Deviation Ratio:less than 0.5%
10. Set Angle:Voltage·Current:±0.2%

 

Angle:±0.30
Pick-up Current:±1%
11. Built-in Standard CT:0.1 range, Rated Load 2VA
12. Display Accuracy:
     Voltmeter:±2%F.S.±2digits
     Current Meter:±2%F.S.±2digits
     Ammeter:±2%F.S.±2digits
13. Operating Power Supply:AC220V 50/60HZ
14. Size and Weight:W525×H490×D345mm Approx. 30kg
※ Additionally,there are DAC-3100 series precise three-phase(4 cables) phantom burden testing current and high accuracy.Various capacities can be controlled via computer.

 
Direct Reading Iron Loss Tester
AUTOMATIC SCHERING BRIDGE
Magnetic Characteristics Measuring Equipment
Lamination
  Stator Tester
■Automatic
Phase Rotation Checker

■Hot Line Coil Resistance & Temperature Meter
Hot Line Coil Resistance
Meter
■Hot Line Winding Coil Resistance Tester for Inverter Power

■Digital Micro Ohmmeter
■Contact Resistance Meter
■Automatic Instrument Transformer Test Set
■Insulation Diagnosis Testing System for High Voltage Machines

■Phantom Burden
■Instrument Transformer Test Set

■Portable Dummy Load Testing Set
■Precision Dummy Load Testing Set for 3 phases

■C & tan& Automatic Measuring Set(DAC-ASM-6)
■C &
tan& Automatic Measuring Set(DAC-ASM-3E)
■Insulation Material Auto Schering Bridge
■Capacitance Automatic Schering Bridge
■DAC-5021
■Capacitance Meter
■Liquid Eletrode(DAC-OBE-2)
■Standard Capacitor
■Partial
Discharge Measuring Set
■High
Voltage Insulation Tester
          the last   teh next