Model
Phantom Burden DAC-PBVC-7
PHANTOM BURDEN
○Application Features:
① This set is a new-type burden(Japanese Patent Product) combined
by actual burden of resitance and reactance of meter transformer
and convertor.
② PT,CT shared,minitype and portable
③ Main Unit Max. Set 100VA。
④ Zero burden can be set using compensation loop
⑤ 500VA(PT)burden can be set using option enlarged load box.
|
○Technical
Index:
① Rated Secondary Voltage:110V,110/√3V in PT Mode
Rated Secondary Current:5A,1A in CT Mode
② Measuring Voltage:2~120% of the Rated in PT Mode
Measuring Current:2~120% of the Rated in CT Mode
③ Burden Power Rate:Lag 0.20~1~0.80 Lead
④ Set Burden: 0.000~100.0VA in PT Mode
0.000~100.0VA in CT Mode
⑤ Down-lead Compensation: 0~1.000Ω in CT Mode
⑥ Burden Set Accuracy:±4% Less than 1/10 of the Rated
±10% |
|
⑦ Output Interface:GP-IB Standard Setup
⑧ Operating Power Supply:AC220V 50/60Hz
⑨ Size and Weight:W430×H200×D450mm 20kg
⑩ Other Options:
○ Enlarged Burden BoxDAC-FBV-1(100VA for PT)
DAC-FBV-2(400VA for PT)
DAC-FBC-1(100VA for CT)
○ Burden Setup for PT,CT
DAC-PBV-7 for PT
DAC-PBC-7 for CT
|
|
| □Instrument
Transformer Test Set□ |
Instrument
Transformer Test Set Model DAC-VCTT-6
INSTRUMENT TRANSFORMER TEST SET
○Testing Object:PT, CT(transformer,
convertor)
○Application Features:Measure ratio
error and phase angle of PT or CT, easy to handle, minitype
and portable, field-applicable.
○Technical Index:
① Measuring Method Comparative Test against Standard Meter
② PT, CT: ○ Transformer Rated Secondary Voltage 220V,220/√3V
○ Convertor Secondary Rated Current 5A、1A |
③
Measuring Range:
Rated Voltage˙Current:2~200%
| Measuring Range |
Display |
| Ratio Error |
Phase Angle |
Ratio Error |
Phase Angle |
| 2%
|
20m |
0~±1.999% |
0~±19.99m |
| 20% |
200m |
0~±19.99% |
0~±199.9m |
④ Resolution:
| Measuring Range |
Ratio Error |
Phase Angle |
| 2% | 0.001% |
0.01m |
| 20% | 0.01%
|
0.1m |
|
|
⑤ Measuring Accuracy:
Ratio Error±(3%RDG Error+4digits)
Phase Angle ±(3%RDG Error +4digits)
⑥ Operating Power Supply: AC220V 50/60Hz
⑦ Size and Weight: W430×H180×D320 10kg
|
|
□可搬型虚负载试验装置□
□精密三相3线式虚负载试验装置□ |
电能表现场校验用虚负载装置Model DAC-PPS-1
○Measuring Object:Dummy load for
ammeter field testing
○Application:can be assembled
with phantom burden of single-phase,three-phase (3 cables),
three-phase (4 cables) ammeter field testing, uninfluenced by
voltage and frequency changes, ensure a stable testing.
|
○Technical
Index:
1. Testing Objects:12W,33W,34W
2. Rated Voltage:220V、100V
3. Rated Current:5A
4. Measuring Voltage:80、90、100、110、120% of Rated Voltage
5. Measuring Current:6、5、2.5、1、0.5、0.25A
6. Latent Flunctuation:110% of Rated Voltage
7. Pick-up Current:50、20、15、12.5mA
8. Output Stability:±0.1%
9. Output Wave Deviation Ratio:less than 0.5%
10. Set Angle:Voltage·Current:±0.2%
|
|
Angle:±0.30
Pick-up Current:±1%
11. Built-in Standard CT:0.1 range, Rated Load 2VA
12. Display Accuracy:
Voltmeter:±2%F.S.±2digits
Current Meter:±2%F.S.±2digits
Ammeter:±2%F.S.±2digits
13. Operating Power Supply:AC220V 50/60HZ
14. Size and Weight:W525×H490×D345mm Approx. 30kg
※ Additionally,there are DAC-3100 series precise three-phase(4 cables) phantom burden testing current and high accuracy.Various capacities can be controlled via computer. | |